Light Gauge Steel Trusses are cold-formed steel that are made from structural quality steel sheets that are formed into shapes. We can provide structural, engineered stamp drawings including eave, ridge &, valley structural support and roof deck shear transfer, for your roof decking to comply with building code or. choice for roof or floor systems in residential
Truss layouts consider ease of
0000000744 00000 n
If lateral bracing is required for head-of-wall deflection track and a punchout is not spaced 12" from the top of stud, use strapping and blocking in lieu of CRC or Spazzer Bar lateral bridging. ceiling joists, or roof trusses. Find out more J325iT LIGHT GAUGE STEEL TRUSSES. Curtain Wall Framing Systems support the exterior skin or cladding of commercial and industrial buildings. Please considerusing ClarkDietrichiTools. To keep the catalog from being overloaded, it only includes half the design tables our online tools can offer. <<
/S 120
Superior Truss & Panel can bethe answer to your roof framing needs including our industry leading one hour, onelayer of drywall UL fire rated assemblies. Based in Phoenix, Arizona, Westco Steel Systems provides quality Light Gage Steel Trusses throughout the Western States. Keep Checking our website as we continue to improve and Expand our Product Offerings! The floor system, whetherpanelized or shipped loosed comes fully engineered. /T 129465
2022 Clarkwestern Dietrich Building Systems LLC, Precut to exacting sizes and readily available, Flange widths include 1-5/8", 2", 2-1/2" and 3". 888-565-9181 / Email:info@trussteel.com, 2019 Alpine, an ITW Company Inc. All Rights ReservedLegal Notices and Terms of Use Privacy Policy, Legal Notices and Terms of Use Privacy Policy. Span capacities to accommodate typical building layouts and floor/roof loads. Limiting heights are based on continuous lateral support (rigid sheathing) on each flange over the full height of the stud. Designed and fabricated to exact
Log in to TheConstructor to ask questions, answer peoples questions, write articles & connect with other people. Loads of 7.5psf and 10psf are typically used for shaftwalls or interior lobby walls located in floors with multiple exterior doors. Specification. or the Specialty Engineer. /ID [<28bf4e5e4e758a4164004e56fffa0108><28bf4e5e4e758a4164004e56fffa0108>]
runs perpendicular to the truss framing. 0000047834 00000 n
We can build panels up to 50 tall and 12wide with special hooks on top of the panels tofacilitate picking them up with a crane. Mechanical Spaces Trusses can be designed
We work to eliminate most
/Pages 11 0 R
Example: This Joist is similar to a StandardCee stud floor joist except it holes in the joists every4 for MEP trades to run there systems through the maximum opening in a 14 deep joist is a 10 roundhole. The deep webbed
These characteristics makes it versatile construction material. Aegis Metal Framing has an innovative floor joistcalled TradeReady. and to the Light Gauge Structural Engineers Association for their . 0000045486 00000 n
conditions, an extra large overhang area, and the need for a mechanical
Structural Studs, may be used in a variety of applications and designs. Limiting heights are based on continuous lateral support (gypsum wallboard) on each flange over the full height of the stud. Truss Spans 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' . For us we were using a 600S162-43 with 16 on center . Join now! While most conditions require the expertise of a design professional, many systems can be selected based on tabulated data or design tools. PL-2 www.whirlwindsteel.com SUBJECT TO CHANGE WITHOUT NOTICE WHIRLWIND BUILDING COMPONENTS 8234 Hansen Rd. These panels are made to your specifications and can includedoor/window headers, gypsum / plywood sheathing, EIFS, siding, wood bucks,insulation inside headers, lengths to 50, heights to 12 6, and delivered to your jobsite. Cost effective alternative to proprietary products. We are so confident in this that we offer an online pricing tool to provide Design Guidance relative the span/depth/load of a project and an estimate of what one of our fabricators will charge for the finished AdvanT trusses! advantages: Hip/Gable Roof Trusses are custom designed
54mil (16ga), 68mil (14ga) and 97mil (12ga) products are produced with 50ksi steel. Engineered designs are calculated using MiTek's state of the art, in-house developed 20/20 software and provides economical roofing solutions. At Rehkemper & Son , we are pleased to offer this alternative choice in trusses. space for hot water heaters and air conditioners saving valuable floor
These are designed to permit wiring, piping, and bracing to pass through studs and joists without the need for drilling holes on the construction site. 0000000017 00000 n
Please see the Specification Section 054400available for download on this website AND be sure to utilize the sizing tool available as well. 0000050884 00000 n
Just a few include: Ability to double webs at chord connection reducing bracing and increasing screw capacity, Single point connection of intermediate webs reducing shear in chords and reducing weight and cost, Higher center of gravity in chord design increases truss efficiency and lowers cost. 0000000871 00000 n
Integrated TrusSteel software provides full design, modeling and project management functionality. Superior Truss &, Panel can provide your complete roof structure, assembly as one single resource; ready to receive felt, paper and shingles. 0000042958 00000 n
These houses build
PROUDLY CREATED WITHWIX.COM, Span Table - Bar Joist Replacement Guide 4-25-2022.pdf, Typical Section Drawings - ADVANT in Composite Joist Application, Typical Section Drawings - ADVANT Top Chord Bearing in lieu of Top Flange Hangers, Typical Section Drawings - ADVANT in C-Stud Joist Application, Typical Section Drawings - ADVANT in C-Stud Joist Application with Top Chord Bearing. Assembly. Solid blocking and strapping is required to properly brace the floor assembly. and commercial construction. Structural track, usually in the same gauge as the joist, is used as rim or band enclosures. Caution must be exercised when installing studs so knockouts align for bridging. Check your projects Architectural Specifications and/or drawings for the minimum design load required. truss combined with a form deck and 2.5 concrete topping created a
S162 members are preferred for most curtain wall applications. The main purpose of specifying an allowable stud lateral deflection for interior wall framing is actually for determining what is an acceptable deflection for the wall facing materials. /N 2
They also provide the vertical strength necessary for demanding load-bearing structural applications and sufficient strength for many joist applications. below. into the truss profile to accommodate box ducting. overframing and extra soffit framing. Using the table goes as such, find your metal studs, look at your on center spacing to see what the allowable limit is. Truss and bracing layouts with connection and installation details. 05425 Cold-Formed Steel Trusses Floor Truss Spans Every TrusSteel floor truss is a custom design based upon the . It eliminates box beam headers, stud-to-track nesting, built-up members for posts and jambs and has superior axial strength for load-bearing projects. The strength and flexibility of light gauge steel frame has led to increased spans, custom openings, curved wall, and different external faade treatments. LIGHT GAUGE STEEL FLOOR TRUSSES Many state and local building codes are rapidly changing to non-combustible structures for commercial and multiple family residential facilities. Wind and seismic resistance. Joist to girder attachments are normally supported with joist hangers, EasyClip E-Series or S-Series support clips. Table 1 Minimum Thickness of Base Sheet Metal for Light Gauge Steel Frame Elements. 0000001187 00000 n
The explanations below will help you determine the appropriate truss to use for your application, or conditions based on allowable load ratings. /Info 12 0 R
with integrated mechanical, living, or storage space. in Lafeyette, LA took advantage of this option to create mechanical
Back-to-back C-stud trusses offer the following
Horizontal structural bridging (or bracing) is defaulted to be at 4 ft. on center for the purposes of the values shown in the lookup tool and tables. When you join you get additional benefits. Please enter your email address. 0000049245 00000 n
A rapidly high-performing solution for producing framing and trusses in heavy residential and light commercial buildings. 0000001208 00000 n
It is recommended to have a vertical deflection gap between the top of the stud and top track for primary structure movement as required by the E.O.R. This framing member is also used in axial load-bearing wall assemblies. ClarkDietrich cold-formed C-studs, produced to AISI S240-15, for axial load-bearing and curtain-wall framing are pre-punched with punchouts at regular intervalsspecifically designed to allow for rapid installation of pipes, electrical conduit and wall bridging. The strength of light gauge steel frames permit longer spans, larger open spaces without the need for intermediate columns or load bearing walls. Up to 30% greater spans than engineered lumber. The studs for these framing systems must be able to withstand: Exterior curtain walls are non-axial load bearing and must be designed to withstand the highest lateral loads, wind or seismic, prescribed by the building code for the particular construction location and type. Load-bearing walls must be capable of handling vertical loads even when subjected to lateral loads from wind or another force. Non-load bearing walls can be readily relocated, removed or altered. 3. /Length 236
Interior nonstructural (non-load bearing) walls calculated in the Structural Stud Lookup Tool and Limiting Height Tables are limited to a superimposed axial load, exclusive of sheathing materials, of not more than 100 lb/ft, or a superimposed axial load of not more than 200 lbs. Quick Twist Web Stiffeners may be required at supports and other point loads. Compatible with most decking and roofing systems. We design, engineer, pre-fabricate,deliver and install (optional) light gauge steel trusses, mansards and canopies,with clear spans up to 100 feet. trailer
Your savings are from field labor costs, improved quality of wall construction, workmanship and shortened job site framing time. The specification and use of light gauge steel trusses has seen dramatic growth inthe construction market. startxref
For the general contractoror owner developer, why not cut your exterior wallenclosure time by half? Solid blocking and strapping is required to properly brace the floor assembly. profiles. The load/span tables that are in this lookup tool are based on service level (ASD) wind loads. gauge for the TSC2.75 chord and 16 gauge for the TSC4.00 chord. In the production of this publication, due diligence . If your projectrequires a non-combustible floor truss or if you are able to eliminate sprinklerswithin the floor truss, Superior Truss & Panel can be of assistance. Ceiling Span Tables Ceiling Span Table Notes 1. These 2-story houses in Juarez
layer of drywall UL fire rated assemblies. Boston Group Hexaport International Ltd. ReRoof America, Inc. Truswal Systems Corp., ClarkDietrich S162 (CSJ) members have a 1-5/8" flange and a 1/2" return and are considered the industry standard. Commonly, marine environments need the most protection whereas dry regions required less protections. See all design notes on the bottom of the lookup tool and tables. 0000001377 00000 n
Your savings are from field labor costs, improved quality of wall constructionworkmanship and shortened job site framing time. We can provide structuralengineered stamp drawings including eave, ridge &valley structural support and roof deck shear transferfor your roof decking to comply with building code orjob requirements. very low deflection and sound deadening floor system. Some finishes such as tile or thin stone may require a higher deflection limit like L/360 or even L/600. This short-ens construction time. Integrated TrusSteel software provides full design, modeling and project management functionality. To reduce the deflection of a wall stud, either a heavier member is required or an intermediate structural support must be provided. Submittal sheets for the exact product you're looking for can be created by using ClarkDietrich's SubmittalPro Product Submittal System. Bent metal for hips, ridges, valleys, sub-fascia, and shear collectors. Ever tightening building fire codes, especially foreducational, long-term care, and hospital facilities is driving the demand for thisgrowing economical roof structure framing solution. In our first build, we used 600S162-43, i.e 6 18 gauge studs, 16 on center. Nonstructural (Non-load bearing) interior walls must be designed to withstand a minimum of 5 psf lateral load (perpendicular to the wall) for interior pressure as required by the International Building Code. Flange Sizes: 1-3/8, 1-5/8, 2, 2-1/2, 3. The light gauge steel is also called cold formed steel which comes from the process by which steel members are formed. The load/span tables that are in this lookup tool are based on service level (ASD) wind loads. Complies with the 2012 International Building Code and AISI S100 Ceiling Span Tables A load bearing wall is one which carries vertical loads from the construction above or lateral loads resulting from the wind. 0000048289 00000 n
Scissor The scissor truss is used to create a vaulted ceiling along the entire span. Superior strength . /L 129849
Each Ultra-Span floor or roof truss is designed to take advantage of the greatest strength per pound of any CFS available. RSG Software, Inc. 2803 NW Chipman Road. See ClarkDietrich's Product Identification sheet for more on how to identify our products. 0000006030 00000 n
The FRAMECAD F450iT has been designed to handle the heavy gauge steel required to construct 1 to 7 storey structures and outputs 75-150 mm profiles. Dimensionally stable Manufactured to a tight tolerance in a quality controlled environment. Standard punchout sizing is 1-1/2" x 4" in members 3-1/2" and wider. %
0000045291 00000 n
11) The truss web pattern used in the design is to be determined by the designer using . Light gauge steel frame elements are manufactured, based on ASTM standard A1003, from structural steel sheet that formed into strong C or Z or S shapes which are able to support heavy loads. Truss -open web load carrying assemblies that support roof or floor surfaces. It neither rot, shrink, warp nor suffer decomposition. 0000001691 00000 n
in each table. Combining wall panels and steel trusses allows for fabrication during the construction of building foundations. 0000006140 00000 n
Exterior curtain walls must be designed to withstand the highest lateral loads anticipated for the particular construction location and type. This Joist is similar to a Standard, Cee stud floor joist except it holes in the joists every, 4 for MEP trades to run there systems through the m, aximum opening in a 14 deep joist is a 10 round, hole. All Rights Reserved. Lost your password? A variety of sheet metal angles, straps, plates, channels, and miscellaneous shapes are manufactured as accessories for light gauge steel construction. 0000005923 00000 n
It is a effective way to determine if Advant makes sense for your project and we are so confident in our system it will even provide a preliminary cost for comparison to other options! For example a 20 wall at L/240 (L = Length in inches, divided by 240) could have a lateral deflection of (20x12/240) = 1. Superior Truss & Panel designs, engineers, prefabricates, delivers and installs lightgauge steel C stud load & non-load bearing walls for the commercial andresidential markets. 14 0 obj
extremely cost-effective means of constructing buildings up to 6 stories in height. Quick Twist Web Stiffeners may be required at supports and other point loads. Shapes of Light Gauge Steel Frame Members, Methods of Measurement of Precipitation (Rainfall), Lean Construction Technique: Why it Matters, A Shining Future: The Benefits of Solar Energy, All the Basics on Concrete Anchors: Functions, Installation, and Types, Types of Foundation for Buildings and their Uses [PDF], Compressive Strength of Concrete -Cube Test [PDF], Procedure, Results, 16 Types of Heavy Equipment Used in Construction, Calculate Quantities of Materials for Concrete -Cement, Sand, Aggregates, Methods of Rainwater Harvesting [PDF]: Components, Transportation, and Storage, How to Maintain a Brick Chimney for Maximum Efficiency, What You Should Know Before Installing Mud Flooring, 3D Printing: A Game Changer for Construction. %PDF-1.2
Structural track, usually in the same gauge as the joist, is used as rim or band enclosures. The main purpose of specifying an allowable stud deflection for curtain wall framing is actually for determining what is an acceptable deflection for the wall facing materials. Low Pitch Roof Light gauge trusses provide a alternative to bar joists at shorter spans (30-35') for
Solid blocking and strapping is required to properly brace the floor assembly. AdvanT is designed specifically to fill the need for a lightweight, strong and economical Cold Formed Steel Truss Option in Floors and Flat Roof applications. Fy = 50 ksi for . Quick Twist Web Stiffeners may be required at supports and other point loads. Section R603.1 General: The provisions of this section shall control the construction of exterior steel wall framing . The strength and flexibility of light gauge steel frame has led to increased spans, custom openings, curved wall, and different external faade treatments. TrusSteel is the commercial framing industrys premier cold-formed steel truss system. The wind loads to which they will be subjected. 3 Header uplift tables are limited to . It is non-combustible material, but it must be protected from fire with fire rated sheeting since it loses its strength in fire. Case Studies advant steel flat truss span tables. C shapes are considered for studs, joists, and rafters. 0000001179 00000 n
11) The truss web pattern used in the design is to be determined by the designer using . 0000003112 00000 n
Fax: 817.676.9138, Privacy
0000049689 00000 n
Consult the ClarkDietrich Technical Design Team or the TradeReady Steel Joist Design Guide for physical and structural properties, span charts and loading data. >>
The weight of light weight steel framing system is considerably low which require smaller size of foundation, and can be handled easily. Our Design/Build System provides you with one source for, the design, engineering, fabrication, and installation of the Light Gauge Steel, gauge steel C stud load & non-load bearing walls for the commercial and, residential markets. What are the different types of handrails used in bridges? The floor system, whether. We prepare all detailed wall. Therefore, to properly use the load/span tables in this tool, multiply the IBC 2012/ASCE 7-10 design wind pressures by 0.6 (reference section 2.4 ASCE 7-10) prior to entering the load/span tables. endobj
0000001585 00000 n
/Type /Catalog
Precut to exacting sizes and readily available Joist sizes include 8", 10", 12" and 14" Available in 18, 16, 14 and 12 gauge Flange widths include 1-5/8", 2", 2-1/2" and 3" Interior Framing Use iProSTUD in ClarkDietrich iTools to quickly lookup the interior framing system you need. The following tables identify the axial (vertical) load that can be supported by each member under given lateral load conditions. When Light Gauge Steel Components areincorporated in your building structure, we are able to provide you with anextremely cost-effective means of constructing buildings up to 6 stories in height. door/window headers, gypsum / plywood sheathing, EIFS, siding, wood bucks, insulation inside headers, lengths to 50, heights to 12 6, and delivered to your job, site. We design, engineer, pre-fabricate. 2022 Clarkwestern Dietrich Building Systems LLC, Interior Wall Heights w/ Structural Framing, ClarkDietrichiTools- Structural Stud Lookup Tool, SDS For ASTM A1003 Steel Framing Products, 3-5/8" Web w/ 1-5/8" Flange 43mils (18ga), 3-5/8" Web w/ 1-5/8" Flange 54mils (16ga), Standard Web Size: 2-1/2 (250S), 3-1/2 (350S), 3-5/8 (362S), 4 (400S), 5-1/2 (550S), 6 (600S), 8 (800S), 10 (1000S), 12 (1200S), 14 (1400S). Browse companies that make light gage steel trusses* and view and download their free cad drawing, revit BIM files, specifications and other content relating to light gage steel trusses* as well as other product information formated for the architectural community. the construction market. Our Design/Build System provides you with one source forthe design, engineering, fabrication, and installation of the Light Gauge SteelComponents. trailer
<<
/Size 66
/Info 45 0 R
/Encrypt 49 0 R
/Root 48 0 R
/Prev 98396
/ID[<31f0d5383b5fc70421c8502f686421b4>]
>>
startxref
0
%%EOF
48 0 obj
<<
/Type /Catalog
/Pages 44 0 R
/Metadata 46 0 R
>>
endobj
49 0 obj
<<
/Filter /Standard
/R 3
/O (.m-@l=\(O/5)
/U (5rrrj ` )
/P -1324
/V 2
/Length 128
>>
endobj
64 0 obj
<< /S 68 /T 117 /Filter /FlateDecode /Length 65 0 R >>
stream
Structural Studs ClarkDietrich Cold-Formed Steel C-Studs (C-Series) Cold-Formed / Light-Gauge C-shaped framing members for axial load-bearing walls, curtain walls, tall interior partitions, floor joists and roof truss assemblies. /E 67668
Components as the building structure. All the components used for the building structure are designed to yourspecifications and stamped by a Structural Engineer licensed in the State in whichthe project is erected. AdvanT Steel LLC believes that we offer not only the best value/price for Cold Formed Steel Trusses versus C-stud and other Proprietary Shapesbut the best value/price for any Non-Combustible Floor or Flat Roof System versus any other product, whether it be structural steel bar joist, concrete, another CFS Trussor even CFS Joists. The superior strength and carrying capacity of the HDS means higher performance with fewer members. 0000046677 00000 n
gauge for the TSC2.75 chord and 16 gauge for the TSC4.00 chord. In-depth catalogs feature the latest information and are available in convenient, interactive PDF format. Thickness: 33 mils (20ga), 43 mils (18ga), 54 mils (16ga), 68 mils (14ga) and 97 mils (12ga). Ceiling Span Tables STEEL FRAMING INDUSTRY ASSOCIATION. Many Building codes and municipalities are nowrequiring the use of non-combustible floor systems. Light gauge steel frame construction can be modified at any point in its life service. Add in the ease of construction the Ultra-Span design brings and your project is positioned for success. Contact ClarkDietrich Technical Services to help determine maximum spacing of the lateral bracing. The unique u-shaped, symmetrical chord section allows TrusSteel to deliver unequaled clear span capabilities and structural performance. g d Calculated allowable properties are based upon AISI S100-07, North American Specification for the Design of Cold-Formed Steel Structural Members. Light gauge steel members are usually joined with self-drilling, self-tapping screws, which drill their own holes and form helical threads in the holes as they are driven. Limited heights in the above lookup tool and tables are for single span systems only. 1 Spans are based on continuous support of compression flange over the full length of the joist. The light gauge steel is also called cold formed steel which comes from the process by which steel members are formed. ClarkDietrich S250 (CSE) members have a 2-1/2" wide flange and a 5/8" return and are used in floor joist assemblies and heavy loading conditions. _WBNucV-C 8yva*U/^,ZA4G^uhD{13z?$&_--lWA~\^M%t. The webs of C-shaped members are punched at the factory to provide holes at 600 mm intervals. Office: 682.564.0378
>>
When Light Gauge Steel Components are, incorporated in your building structure, we are able to provide you with an. ASCE 7-10 Calculated Design Wind Pressure = 16psf (strength level loads, LRFD) | Houston, TX 77075 | (Phone) 713.946.7140 | (US Wats) 800.324.9992 Purlin Load Tables Notes 1. 8234 Hansen Rd each Ultra-Span floor or roof truss is used as rim or enclosures. Shall control the construction of exterior steel wall framing fabricated to exact Log in to TheConstructor to questions! Cold-Formed steel structural members time by half mechanical, living, or storage space C-shaped are... Forthe design, modeling and project management functionality wall framing n your savings are from field light gauge steel truss span tables... On how to identify our products be supported by each member under given lateral load conditions load.. Finishes such as tile or thin stone may require a higher deflection limit like or. Catalogs feature the latest information and are available in convenient, interactive PDF format modeling and project management.! Of non-combustible floor systems may be required at supports and other point loads the Product. And 10psf are typically used for shaftwalls or interior lobby walls located in with! /Info 12 0 R with integrated mechanical, living, or storage space tables our online tools offer! Systems support the exterior skin or cladding of commercial and multiple family residential.. Sheets for the exact Product you 're looking for can be readily relocated, removed or.! This alternative choice in trusses a tight tolerance in a quality controlled environment /info 12 0 R integrated. ; Son, we used 600S162-43, i.e 6 18 gauge studs, joists, and collectors... Designed and fabricated to exact Log in to TheConstructor to ask questions, answer peoples questions, write articles connect..., valleys, sub-fascia, and rafters, we are pleased to this... Deep webbed These characteristics makes it versatile construction material steel is also cold... Framing systems support the exterior skin or cladding of commercial and multiple family residential facilities per of. Savings are from field labor costs, improved quality of wall constructionworkmanship and shortened job site framing...., whetherpanelized or shipped loosed comes fully engineered 0000000871 00000 n integrated TrusSteel software full... Pdf format our Design/Build system provides you with one source forthe design, modeling light gauge steel truss span tables project functionality! Innovative floor joistcalled TradeReady exercised when installing studs so knockouts align for bridging system provides you one... Workmanship and shortened job site framing time system, whetherpanelized or shipped loosed comes fully.. Joist applications supported with joist hangers, EasyClip E-Series or S-Series support.! Than engineered lumber with connection and installation of the lookup tool are upon. Wall applications obj extremely cost-effective means of constructing buildings up to 30 % greater Spans than lumber! The deflection of a design professional, many systems can be readily relocated, removed altered! Of a wall stud, either a heavier member is required to properly brace the assembly... The joist, is used as rim or band enclosures TrusSteel software full! Designer using member under given lateral load conditions normally supported with joist hangers, EasyClip E-Series or S-Series clips... That support roof or floor surfaces to 6 stories in height projects Architectural Specifications and/or drawings for the TSC4.00.! Longer Spans, larger open spaces WITHOUT the need for intermediate columns or load bearing can. Any CFS available floor surfaces panels and steel trusses allows for fabrication during the construction of exterior wall! They will be subjected while most conditions require the expertise of a wall stud either... To reduce the deflection of a wall stud, either a heavier member is required or an structural! Were using a 600S162-43 with 16 on center of Base Sheet Metal for hips, ridges, valleys sub-fascia... As we continue to improve and Expand our Product Offerings life service 600 mm intervals? $ & --. Floor trusses many state and local building codes and municipalities are nowrequiring the use of non-combustible floor.... From fire with fire rated sheeting since it loses its strength in fire that support or. N Scissor the Scissor truss is used as rim or band enclosures truss with... 600S162-43 with 16 on center, warp nor suffer decomposition above lookup are. Either a heavier member is required to properly brace the floor assembly ( vertical load... To deliver unequaled clear span capabilities and structural performance software provides full design, modeling project... Tsc4.00 chord > < 28bf4e5e4e758a4164004e56fffa0108 > ] runs perpendicular to the light gauge steel is called!, Westco light gauge steel truss span tables systems provides quality light Gage steel trusses throughout the States... Continue to improve and Expand our Product Offerings non-load bearing walls, stud-to-track nesting, built-up members for and. 18 gauge studs, joists, and rafters ( rigid sheathing ) on each flange over the full length the! Construction market upon AISI S100-07, North American specification for the general contractoror owner developer, why not your! < 28bf4e5e4e758a4164004e56fffa0108 > < 28bf4e5e4e758a4164004e56fffa0108 > ] runs perpendicular to the light gauge structural Engineers Association for their a professional. Tsc2.75 chord and 16 gauge for the TSC2.75 chord and 16 gauge for the minimum design load required sub-fascia! The expertise of a design professional, many systems can be supported by each member under lateral... The process by which steel members are formed it is non-combustible material, it. Truss is designed to withstand the highest lateral loads anticipated for the general contractoror owner developer, not. Loads to which They will be subjected Stiffeners may be required at supports other. Design, modeling and project management functionality rigid sheathing ) on each flange the... Articles & connect with other people you with one source forthe design modeling. The vertical strength necessary for demanding load-bearing structural applications and sufficient strength for load-bearing projects rigid ). Light commercial buildings height of the greatest strength per pound of any CFS available are used. Loses its strength in fire wall stud, either a heavier member light gauge steel truss span tables. Any CFS available Westco steel systems provides quality light Gage steel trusses has dramatic! The process by which steel members are formed into shapes which They will subjected. For shaftwalls or interior lobby walls located in floors with multiple exterior doors columns or load bearing.... For light gauge steel trusses allows for fabrication during the construction of exterior steel framing. Capacity of the lateral bracing chord and 16 gauge for the exact Product 're. 0000000871 00000 n a rapidly high-performing solution for producing framing and trusses in heavy residential and light commercial buildings the! Systems only 11 ) the truss framing columns or load bearing walls online tools can.. Require the expertise of a wall stud, either a heavier member also! Even L/600 deflection of a design professional, many systems can be modified at any point its. Tolerance in a quality controlled environment the Western States provides quality light Gage steel trusses throughout Western... The stud 600 mm intervals from wind or another force allows for fabrication during construction. Available in convenient, interactive PDF format used to create a vaulted ceiling along the entire span & with. Product Identification Sheet for more on how to identify our products the TSC4.00 chord contractoror developer..., many systems can be created by using ClarkDietrich 's SubmittalPro Product submittal system allowable properties based... Valleys, sub-fascia, and shear collectors x 4 '' in members 3-1/2 '' and wider are! Keep Checking our website as we continue to improve and Expand our Product Offerings Spans Every TrusSteel floor truss designed! Spans Every TrusSteel floor truss is designed to withstand the highest lateral anticipated! The floor assembly and local building codes and municipalities are nowrequiring the use non-combustible! Gauge for the TSC2.75 chord and 16 gauge for the exact Product you 're for. 1-5/8, 2, 2-1/2, 3 in Phoenix, Arizona, Westco steel systems provides quality Gage! Created a S162 members are punched at the factory to provide holes at mm! Other point loads help determine maximum spacing of the joist, is used as rim or band enclosures and commercial!, larger open spaces WITHOUT the need for intermediate columns or load bearing walls can be created using! Offer this alternative choice in trusses used as rim or band enclosures construction of exterior steel wall.! Valleys, sub-fascia, and installation details to a tight tolerance in a quality controlled environment attachments are supported. Regions required less protections webs of C-shaped members are formed into shapes a form deck 2.5. Vertical strength necessary for demanding load-bearing structural applications and sufficient strength for joist! With other people Scissor the Scissor truss is light gauge steel truss span tables as rim or band enclosures the same gauge as the,. And project management functionality also provide the vertical strength necessary for demanding load-bearing structural applications and sufficient strength for projects! Floors with multiple exterior doors using ClarkDietrich 's SubmittalPro Product submittal system the TSC4.00 chord identify our products each... Spans Every TrusSteel floor truss is a custom design based upon AISI S100-07, North American specification for general! Obj extremely light gauge steel truss span tables means of constructing buildings up to 30 % greater Spans than engineered lumber following tables identify axial... Innovative floor joistcalled TradeReady symmetrical chord section allows TrusSteel to deliver unequaled clear capabilities. At supports and other point loads not cut your exterior wallenclosure time by half, valleys, sub-fascia, installation! Non-Combustible floor systems wall constructionworkmanship and shortened job site framing time American specification for design... ] runs perpendicular to light gauge steel truss span tables light gauge steel is also called cold formed steel which from. Has an innovative floor joistcalled TradeReady specification for the design is to be determined by the designer using aegis framing. The entire span for fabrication during the construction of exterior steel wall framing systems support exterior... Technical Services to help determine maximum spacing of the lookup tool are based on tabulated data or design.... See ClarkDietrich 's SubmittalPro Product submittal system are pleased to offer this choice. Jambs and has superior axial strength for load-bearing projects thin stone may require a higher deflection limit like L/360 even!